Product Description

Because of our well equipped infrastructure and timely delivery, we as a prime manufacturer, supplier and trader can offer our range of Remote I-O Systems. Accessible in various details and measurements, these units are known for their shock proof nature. Our interface units discover applications in different segments like training, business, and government. The whole assembling procedure of this Remote I-O Systems is done under the strict supervision of our professional technicians and talented experts.

Features :

  • Consistency in any condition
  • Dimensionally precise
  • Easy installation
  • Superb execution

HART Transmitter Power Supply, Input Isolator FB3205B2

  • 4-channel
  • Inputs Ex ia
  • Power supply for 2-wire transmitters with 4 mA ... 20 mA
  • Supply circuit 15 V (20 mA)
  • Input from active signals of 4-wire transmitters
  • Installation in suitable enclosures in Zone 1 or Zone 21
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
  • Module can be exchanged under voltage (hot swap)
  • Datasheet excerpt: Technical data of FB3205B2

Technical Specification :

Supply

Connection

backplane bus

Rated voltage

12 V DC , only in connection with the power supplies FB92**

Power dissipation

1.5 W

Power consumption

3 W

Internal bus

Connection

backplane bus

Interface

manufacturer-specific bus to standard com unit

Input

Number of channels

4

Suitable field devices

transmitters for pressure, differential pressure, level, flow, temperature, etc.

Connection

2-wire transmitter (HART): supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-
3-wire transmitter: supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16- measuring circuit: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-
4-wire transmitter (separately powered): measuring circuit: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-

Input resistance

15 Ω (channel I: 3, 4; channel II: 7, 8; channel III: 11, 12; channel IV: 15, 16)

Line fault detection

can be switched on/off for each channel via configuration tool , configurable via configuration tool

Short-circuit

Ex works settings: > 22 mA configurable between 0...26 mA

Open-circuit

Ex works settings: < 1 mA configurable between 0...26 mA

Transmitter supply voltage

15 V at 20 mA

Transfer characteristics

Deviation


After calibration

0.1 % of the signal range at 20 °C (68 °F)

Resolution

12 Bit (0 ... 26 mA)

Refresh time

100 ms

Indicators/settings

LED indicator

Power LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1-4) red: line fault (lead breakage or short circuit)

Directive conformity

Electromagnetic compatibility


Directive 2014/30/EU

EN 61326-1:2006

Conformity

Electromagnetic compatibility

NE 21:2007

Degree of protection

IEC 60529:2000

Ambient conditions

Ambient temperature

-20 ... 60 °C (-4 ... 140 °F)

Storage temperature

-25 ... 85 °C (-13 ... 185 °F)

Relative humidity

95 % non-condensing

Shock resistance

shock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100

Vibration resistance

frequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz

Damaging gas

designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protection

IP20 (module) , a separate housing is required acc. to the system description

Connection

removable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14...1.5mm2) or screw terminals (0.08...1.5mm2)

Mass

approx. 750 g

Dimensions

57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)

Data for application in connection with hazardous areas

EC-Type Examination Certificate

BVS 12 ATEX E 101 X

Group, category, type of protection, temperature class

II 2(1) G Ex d [ia Ga] IIC T4 Gb
II (1) D [Ex ia Da] IIIC

Supply


Voltage

27 V

Current

90 mA

Power

588 mW (linear characteristic)

Input


Voltage

0.7 V

Current

2.78 mA

Power

2 mW (trapezoid characteristic curve)

Internal capacitance

242 nF

Internal inductance

0 mH

Galvanic isolation


Input/power supply, internal bus

safe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V

Directive conformity


Directive 2014/34/EU

EN 60079-0:2009
EN 60079-1:2007
EN 60079-11:2012
EN 60079-26:2007

International approvals

ATEX approval

BVS 12 ATEX E 101 X

INMETRO

Brazil: TÜV 14.1597X

Marine approval


Bureau Veritas Marine

22449/B0 BV

HART Transmitter Power Supply, Input Isolator LB3002A2

  • 1-channel
  • Power supply for 2- or 3-wire transmitters with 4mA...20mA
  • Installation in Zone 2 or safe area
  • Supply circuit 15 V (20 mA)
  • Input from active signals of 4-wire transmitters
  • HART communication via field bus or service bus
  • HART communication also for separately powered devices
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD) and Live Zero monitoring
  • Permanently self-monitoring
  • Module can be exchanged under voltage

Datasheet excerpt: Technical data ofLB3002A2

Supply

Connection

backplane bus

Rated voltage

12 V DC , only in connection with the power supplies LB9***

Power dissipation

0.4 W

Power consumption

1 W

Internal bus

Connection

backplane bus

Interface

manufacturer-specific bus to standard com unit

Input

Number of channels

1

Suitable field devices

transmitters for pressure, differential pressure, level, flow, temperature, etc.

Connection

2-wire transmitter (HART): supply circuit: 2/3+, 4/5-
3-wire transmitter (HART): supply circuit: 2/3+, 6- measuring circuit: 4/5+, 6-
4-wire transmitter (separately powered): measuring circuit: 4/5+, 6- HART measuring circuit: 1+, 6-

Input resistance

15 Ω (terminals 5, 6)
236 Ω (terminals 1, 6) HART

Line fault detection

can be switched on/off for each channel via configuration tool , configurable via configuration tool

Short-circuit

Ex works settings: > 22 mA configurable between 0...26 mA

Open-circuit

Ex works settings: < 1 mA configurable between 0...26 mA

Transmitter supply voltage

15 V at 20 mA

Live Zero monitoring

configurable

Transfer characteristics

Deviation


After calibration

0.1 % of the signal range at 20 °C (68 °F)

Resolution

12 Bit (0 ... 26 mA)

Refresh time

100 ms

Indicators/settings

LED indicator

Power LED (P) green: supply
Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
Status LED (1) red: line fault (lead breakage or short circuit)
Status LED (2) yellow: Live Zero monitoring

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU

EN 61326-1:2006

Conformity

Electromagnetic compatibility

NE 21:2007

Degree of protection

IEC 60529:2000

Ambient conditions

Ambient temperature

-20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex)

Storage temperature

-25 ... 85 °C (-13 ... 185 °F)

Shock resistance

shock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100

Vibration resistance

frequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz

Damaging gas

designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protection

IP20 when mounted on backplane

Connection

removable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14...1.5mm2) or screw terminals (0.08...1.5mm2)

Mass

approx. 90 g

Dimensions

16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)

Data for application in connection with hazardous areas

Output

Voltage

27 V

Current

87 mA

Power

575 mW (linear characteristic)

Statement of conformity

BVS 13 ATEX E 038 X

Group, category, type of protection, temperature class

II 3 G Ex nA [ic] IIC T4 Gc

Galvanic isolation


Input/power supply, internal bus

safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V

Directive conformity


Directive 2014/34/EU

EN 60079-0:2012
EN 60079-11:2012
EN 60079-15:2010

International approvals

IECEx approval

BVS 13.0043X


Approved for

Ex nA [ic] IIC T4 Gc

EAC approval

Russia: RU C-IT.MIII06.B.00129

Marine approval

Lloyd Register

15/20021

American Bureau of Shipping

T1450280/UN

Bureau Veritas Marine

22449/B0 BV



546/1, 7th Main, Peenya Fourth Phase, Bengaluru - 560058, Karnataka, India
Mr. Amol Save
   Call Me Free Offline Send SMS Send Inquiry


Buyers Helpdesk

Let tradeindia.com find Quality Suppliers for you!

I agree to abide by all the Terms and Conditions of tradeindia.com
PEPPERL+FUCHS (INDIA) PVT. LTD. All Rights Reserved.